Results 1 - 20 de 84
Filter
1.
Eur J Clin Invest ; 54(6): e14192, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38445798

ABSTRACT

BACKGROUND: High-intensity focused ultrasound (HIFU) emerged as a novel approach for the treatment of localized prostate cancer (PCa). However, prospective studies on HIFU-related outcomes and predictors of treatment failure (TF) remain scarce. MATERIALS AND METHODS: We conducted a multinational prospective cohort study among patients undergoing HIFU therapy for localized, low- to intermediate-risk PCa. Follow-up data on serial prostate specific antigen (PSA), multi-parametric magnetic resonance imaging (mpMRI), targeted/systematic biopsies, adverse events and functional outcomes were collected. The primary endpoint was TF, defined as histologically confirmed PCa requiring whole-gland salvage treatment. Uni- and multi-variable adjusted hazard ratios (HRs) were calculated using Cox proportional hazard regression models. RESULTS: At baseline, mean (standard deviation) age was 64.14 (7.19) years, with the majority of patients showing T-stage 1 (73.9%) and International Society of Urological Pathology grading system Grade 2 (58.8%). PSA nadir (median, 1.70 ng/mL) was reached after 6 months. Of all patients recruited, 16% had clinically significant PCa, as confirmed by biopsy, of which 13.4% had TF. Notably, T-stage and number of positive cores at initial biopsy were independent predictors of TF during follow-up (HR [95% CI] 1.27 [1.02-1.59] and 5.02 [1.80-14.03], respectively). Adverse events were minimal (17% and 8% early and late adverse events, respectively), with stable or improved functional outcomes in the majority of patients. CONCLUSIONS: This interim analysis of a multinational study on HIFU therapy for the management of low-to-intermediate-risk PCa reveals good functional outcomes, minimal adverse events and low incidence of TF over the short-term. Data on long-term outcomes, specifically as it relates to oncological outcomes, are awaited eagerly.


Subject(s)
Prostate-Specific Antigen , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/therapy , Prostatic Neoplasms/pathology , Middle Aged , Aged , Prostate-Specific Antigen/metabolism , Prostate-Specific Antigen/blood , Prospective Studies , Ultrasound, High-Intensity Focused, Transrectal , Treatment Failure , Proportional Hazards Models , Salvage Therapy/methods , High-Intensity Focused Ultrasound Ablation/methods , Multiparametric Magnetic Resonance Imaging , Neoplasm Grading , Cohort Studies
2.
Breast Care (Basel) ; 19(1): 62-72, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38384485

ABSTRACT

Introduction: B3-lesions of the breast are a heterogeneous group of neoplasms, associated with a higher risk of breast cancer. Recent studies show a low upgrade rate into malignancy after subsequent open surgical excision (OE) of most B3-lesions when proven by vacuum-assisted biopsy (VAB). However, there is a lack of long-term follow-up data after VAB of high-risk lesions. The primary aim of this study was to demonstrate whether follow-up of B3 lesions is a beneficial and reliable alternative to OE in terms of long-term outcome. The secondary aim was to identify patient and lesion characteristics of B3 lesions for which OE is still necessary. Methods: This retrospective multicenter study was conducted at 8 Swiss breast centers between 2010 and 2019. A total of 278 women (mean age: 53.5 ± 10.7 years) with 286 B3-lesions who had observation only and who had at least 24 months of follow-up were included. Any event during follow-up (ductal carcinoma in situ [DCIS], invasive cancer, new B3-lesion) was systematically recorded. Data from women who had an event during follow-up were compared with those who did not. The results for the different B3 lesions were analyzed using the t test and Fisher's exact test. A p value of <0.05 was considered statistically significant. Results: The median follow-up interval was 59 months (range: 24-143 months) with 52% (148/286) having a follow-up of more than 5 years. During follow-up, in 42 women, 44 suspicious lesions occurred, with 36.4% (16/44) being invasive cancer and 6.8% (3/44) being DCIS. Thus, 6.6% (19/286) of all women developed malignancy during follow-up after a median follow-up interval of 6.5 years (range: 31-119 months). The initial histology of the B3 lesion influenced the subsequent occurrence of a malignant lesion during follow-up (p < 0.038). The highest malignancy-developing rate was observed in atypical ductal hyperplasia (ADH) (24%, 19/79), while all other B3-lesions had malignant findings ipsi- and contralateral between 0% and 6%. The results were not influenced by the VAB method (Mx-, US-, magnetic resonance imaging-guided), the radiological characteristics of the lesion, or the age or menopausal status of the patient (p > 0.12). Conclusion: With a low risk of <6% of developing malignancy, VAB followed by long-term follow-up is a safe alternative to OE for most B3-lesions. A higher malignancy rate only occurred in ADH (24%). Based on our results, radiological follow-up should be bilateral, preferable using the technique of initial diagnosis. As we observed a late peak (6-7 years) of breast malignancies after B3-lesions, follow-up should be continued for a longer period (>10 years). Knowledge of these long-term outcome results will be helpful in making treatment decisions and determining the optimal radiological follow-up interval.

3.
EJNMMI Res ; 14(1): 17, 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38340184

ABSTRACT

BACKGROUND: Endometriosis is characterized by the ectopic occurrence of endometrial tissue. Though considered benign, endometriotic lesions possess tumor-like properties such as tissue invasion and remodeling of the extracellular matrix. One major clinical hurdle concerning endometriosis is its diagnosis. The diagnostic modalities ultrasound and MRI are often unable to detect all lesions, and a clear correlation between imaging and clinical symptoms is still controversial. Therefore, it was our aim to identify a potential target to image active endometriotic lesions. RESULTS: For our studies, we employed the preclinical radiotracer [111In]In-FnBPA5, which specifically binds to relaxed fibronectin-an extracellular matrix protein with key functions in homeostasis that has been implicated in the pathogenesis of diseases such as cancer and fibrosis. We employed this tracer in biodistribution as well as SPECT/CT studies in mice and conducted immunohistochemical stainings on mouse uterine tissue as well as on patient-derived endometriosis tissue. In biodistribution and SPECT/CT studies using the radiotracer [111In]In-FnBPA5, we found that radiotracer uptake in the myometrium varies with the estrous cycle of the mouse, leading to higher uptake of [111In]In-FnBPA5 during estrogen-dependent phases, which indicates an increased abundance of relaxed fibronectin when estrogen levels are high. Finally, immunohistochemical analysis of patient samples demonstrated that there is preferential relaxation of fibronectin in the proximity of the endometriotic stroma. CONCLUSION: Estrous cycle stages characterized by high estrogen levels result in a higher abundance of relaxed fibronectin in the murine myometrium. This finding together with a first proof-of-concept study employing human endometriosis tissues suggests that relaxed fibronectin could be a potential target for the development of a diagnostic radiotracer targeting endometriotic lesions. With [111In]In-FnBPA5, the matching targeting molecule is in preclinical development.

4.
Acad Radiol ; 31(4): 1400-1409, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37925344

ABSTRACT

RATIONALE AND OBJECTIVES: T2-weighted imaging in at least two orthogonal planes is recommended for assessment of the uterus. To determine whether a convolutional neural network-based algorithm could be used for the re-constructions of uterus axes derived from a 3D SPACE with iterative denoising. MATERIALS AND METHODS: 50 patients aged 18-81 (mean: 42) years who underwent an MRI examination of the uterus participated voluntarily in this prospective study after informed consent. In addition to a standard MRI pelvis protocol, a 3D SPACE research application sequence was acquired in sagittal orientation. Reconstructions for both the cervix and the cavum in the short and long axes were performed by a research trainee (T), an experienced radiologist (E), and the prototype software (P). In the next step, the reconstructions were evaluated anonymously by two experienced readers according to 5-point-Likert-Scales. In addition, the length of the cervical canal, the length of the cavum and the distance between the tube angles were measured on all reconstructions. Interobserver agreement was assessed for all ratings. RESULTS: For all axes, significant differences were found between the scores of the reconstructions by research T, E and P. P received higher scores and was preferred significantly more often with the exception of the comparison of the reconstruction Cervix short of E (Cervix short: P vs. T: p = 0.02; P vs. E: p = 0.26; Cervix long: P vs. T: p = 0.01; P vs. E: p < 0.01; Cavum short: P vs. T: p = 0.01; P vs. E: p = 0.02; Cavum long: P vs. T: p < 0.01; P vs. E: p < 0.01). Regarding the measured diameters, (length of cervical canal/cavum/distance between tube angles) significantly larger diameters were recorded for P compared to E and T (Cervix long (mm): T: 25.43; E: 25.65; P: 26.65; Cavum short (mm): T: 26.24; E: 25.04; P: 27.33; Cavum long (mm): T: 31.98; E: 32.91; P: 34.41; P vs. T: p < 0.01); P vs. E: p = 0.04). Moderate to substantial agreement was found between Reader 1 and Reader 2 (range: 0.39-0.67). CONCLUSION: P was able to reconstruct the axes at least as well as or better than E and T. P could thereby lead to workflow facilitation and enable more efficient reporting of uterine MRI.


Subject(s)
Imaging, Three-Dimensional , Uterus , Female , Humans , Imaging, Three-Dimensional/methods , Prospective Studies , Uterus/diagnostic imaging , Magnetic Resonance Imaging/methods , Neural Networks, Computer
5.
Article in English | MEDLINE | ID: mdl-37549087

ABSTRACT

Speed of sound (SoS) is a novel imaging biomarker for assessing the biomechanical characteristics of soft tissues. SoS imaging in the pulse-echo mode using conventional ultrasound (US) systems with hand-held transducers has the potential to enable new clinical uses. Recent work demonstrated that diverging waves (DWs) from a single element (SE) transmit to outperform plane-wave sequences. However, SE transmits have severely limited power and hence produce a low signal-to-noise ratio (SNR) in echo data. We herein propose Walsh-Hadamard (WH) coded and virtual-source (VS) transmit sequences for the improved SNR in SoS imaging. We additionally present an iterative method of estimating beamforming (BF) SoS in the medium, which otherwise confounds SoS reconstructions due to beamforming inaccuracies in the images used for reconstruction. Through numerical simulations, phantom experiments, and in vivo imaging data, we show that WH is not robust against motion, which is often unavoidable in clinical imaging scenarios. Our proposed VS sequence is shown to provide the highest SoS reconstruction performance, especially robust to motion artifacts. In phantom experiments, despite having a comparable SoS root-mean-square error (RMSE) of 17.5-18.0 m/s at rest, with a minor axial probe motion of ≈ 0.67 mm/s the RMSE for SE, WH, and VS already deteriorate to 20.2, 105.4, and 19.0 m/s, respectively, showing that WH produces unacceptable results, not robust to motion. In the clinical data, the high SNR and motion resilience of VS sequences are seen to yield superior contrast compared to SE and WH sequences.


Subject(s)
Artifacts , Sound , Ultrasonography/methods , Signal-To-Noise Ratio , Phantoms, Imaging
6.
Virchows Arch ; 483(1): 5-20, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37330436

ABSTRACT

The heterogeneous group of B3 lesions in the breast harbors lesions with different malignant potential and progression risk. As several studies about B3 lesions have been published since the last Consensus in 2018, the 3rd International Consensus Conference discussed the six most relevant B3 lesions (atypical ductal hyperplasia (ADH), flat epithelial atypia (FEA), classical lobular neoplasia (LN), radial scar (RS), papillary lesions (PL) without atypia, and phyllodes tumors (PT)) and made recommendations for diagnostic and therapeutic approaches. Following a presentation of current data of each B3 lesion, the international and interdisciplinary panel of 33 specialists and key opinion leaders voted on the recommendations for further management after core-needle biopsy (CNB) and vacuum-assisted biopsy (VAB). In case of B3 lesion diagnosis on CNB, OE was recommended in ADH and PT, whereas in the other B3 lesions, vacuum-assisted excision was considered an equivalent alternative to OE. In ADH, most panelists (76%) recommended an open excision (OE) after diagnosis on VAB, whereas observation after a complete VAB-removal on imaging was accepted by 34%. In LN, the majority of the panel (90%) preferred observation following complete VAB-removal. Results were similar in RS (82%), PL (100%), and FEA (100%). In benign PT, a slim majority (55%) also recommended an observation after a complete VAB-removal. VAB with subsequent active surveillance can replace an open surgical intervention for most B3 lesions (RS, FEA, PL, PT, and LN). Compared to previous recommendations, there is an increasing trend to a de-escalating strategy in classical LN. Due to the higher risk of upgrade into malignancy, OE remains the preferred approach after the diagnosis of ADH.


Subject(s)
Breast Neoplasms , Carcinoma, Intraductal, Noninfiltrating , Phyllodes Tumor , Precancerous Conditions , Humans , Female , Breast/pathology , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Mammography/methods , Biopsy, Large-Core Needle , Precancerous Conditions/diagnosis , Precancerous Conditions/pathology , Phyllodes Tumor/pathology , Retrospective Studies
7.
In Vivo ; 37(3): 1186-1191, 2023.
Article in English | MEDLINE | ID: mdl-37103075

ABSTRACT

BACKGROUND/AIM: To evaluate the impact of high data rate and sampling frequency detector technology compared to standard scan equipment on the image quality in abdominal computed tomography (CT) of overweight and obese patients. PATIENTS AND METHODS: A total of 173 patients were retrospectively included in this study. Objective image quality in abdominal CT was evaluated using comparative analysis with new detector technology prior to market launch and standard CT equipment. Contrast noise ratio (CNR), image noise, volumetric computed tomography dose index (CTDIVol), and figures of merit (Q and Q1) were assessed for all patients. RESULTS: Image quality was superior in the new detector technology for all parameters evaluated. The dose dependent parameters Q and Q1 showed a significant difference (p<0.001). CONCLUSION: A significant increase in objective image quality could be demonstrated using a new generation detector setup with increased frequency transfer in abdominal CT of overweight patients.


Subject(s)
Obesity , Overweight , Humans , Overweight/diagnostic imaging , Retrospective Studies , Radiation Dosage , Obesity/diagnostic imaging , Tomography, X-Ray Computed/methods
8.
Diagnostics (Basel) ; 13(4)2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36832095

ABSTRACT

This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500-b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI (p = 0.001 and p = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values (p = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10-3 mm2/s) and z-DWI (ADC: 0.99 [±0.11] × 10-3 mm2/s; p = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10-3 mm2/s) than in s-DWI (p = 0.090) and z-DWI (p = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time.

9.
In Vivo ; 37(1): 99-105, 2023.
Article in English | MEDLINE | ID: mdl-36593029

ABSTRACT

BACKGROUND/AIM: The aim was to evaluate the effect of a combined precision matrix and high sampling rate on the delineation of anatomical structures and objective image quality in single source CT in a qualitative approach. MATERIALS AND METHODS: An anthropomorphic thoracic phantom was used to evaluate the objective image quality parameters, including image noise, noise power spectrum, image stepness and Q for different CT scanners including high/standard matrix and framing frequency setups. Scan parameters were standardized over all scanners. Additional subjective quality assessment was also performed. RESULTS: A linear mixed effects model was used to determine the effect of sampling rate and image matrix on objective image quality parameters. Noise power spectrum and image noise were significantly influenced by both framing frequency and image matrix. There were significant differences between high and standard frequency/matrix acquisitions. CONCLUSION: Higher framing frequency and image matrix allows for improved image noise texture and objective image quality in CT.


Subject(s)
Tomography, X-Ray Computed , Radiation Dosage , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Phantoms, Imaging
10.
Diagnostics (Basel) ; 13(2)2023 Jan 12.
Article in English | MEDLINE | ID: mdl-36673092

ABSTRACT

The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an abdominal phantom using conventional CT guidance and a laser guidance system. Analysis of pooled results of expert and novice showed a significant reduction of time (277 vs. 204 s, p = 0.001) and of the number of needle corrections (3.28 vs. 1.58, p < 0.001) required when using laser guidance versus conventional technique. No significant improvement in absolute (3.81 vs. 3.41 mm, p = 0.213) or angular deviation (2.85 vs. 2.18°, p = 0.079) was found. With either approach, the expert was significantly faster (conventional guidance: 207 s vs. 346 s, p < 0.001; laser guidance: 144 s vs. 264 s, p < 0.001) and required fewer needle corrections (conventional guidance: 4 vs. 3, p = 0.027; laser guidance: 2 vs. 1, p = 0.001) than the novice. The laser guidance system helped both the expert and the novice to perform CT guided interventions in a phantom faster and with fewer needle corrections compared to the conventional technique, while achieving similar accuracy.

11.
Eur Radiol ; 33(4): 2927-2934, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36350392

ABSTRACT

OBJECTIVES: Augmented reality (AR), which entails overlay of in situ images onto the anatomy, may be a promising technique for assisting image-guided interventions. The purpose of this study was to investigate and compare the learning experience and performance of untrained operators in puncture of soft tissue lesions, when using AR ultrasound (AR US) compared with standard US (sUS). METHODS: Forty-four medical students (28 women, 16 men) who had completed a basic US course, but had no experience with AR US, were asked to perform US-guided biopsies with both sUS and AR US, with a randomized selection of the initial modality. The experimental setup aimed to simulate biopsies of superficial soft tissue lesions, such as for example breast masses in clinical practice, by use of a turkey breast containing olives. Time to puncture(s) and success (yes/no) of the biopsies was documented. All participants completed questionnaires about their coordinative skills and their experience during the training. RESULTS: Despite having no experience with the AR technique, time to puncture did not differ significantly between AR US and sUS (median [range]: 17.0 s [6-60] and 14.5 s [5-41], p = 0.16), nor were there any gender-related differences (p = 0.22 and p = 0.50). AR US was considered by 79.5% of the operators to be the more enjoyable means of learning and performing US-guided biopsies. Further, a more favorable learning curve was achieved using AR US. CONCLUSIONS: Students considered AR US to be the preferable and more enjoyable modality for learning how to obtain soft tissue biopsies; however, they did not perform the biopsies faster than when using sUS. KEY POINTS: • Performance of standard and augmented reality US-guided biopsies was comparable • A more favorable learning curve was achieved using augmented reality US. • Augmented reality US was the preferred technique and was considered more enjoyable.


Subject(s)
Augmented Reality , Students, Medical , Male , Humans , Female , Learning , Ultrasonography , Ultrasonography, Interventional
12.
Acad Radiol ; 30(6): 1129-1140, 2023 06.
Article in English | MEDLINE | ID: mdl-35871059

ABSTRACT

RATIONALE AND OBJECTIVES: High-resolution T2-weighted magnetic resonance imaging (MRI) of the pelvis is the main technique used for diagnosing benign and malignant uterine diseases. However, the procedure may be time-consuming and requires training and experience. Therefore, this study was performed to compare the image quality of standard clinical BLADE (stBLADE) with a prototypical accelerated simultaneous multi-slice (SMS) BLADE procedure with either improved temporal resolution (tr) at the same slice thickness (SL) or improved spatial resolution (sr) with the same examination time and a prototypical isotropic 3D SPACE procedure with inner-volume excitation and iterative denoising. MATERIALS AND METHODS: Patients who underwent clinically indicated MRI of the uterus were included in this prospective study and underwent stBLADE (acquisition time, 2 min 59 s; SL, 4 mm) and SMS BLADE (tr) with the same SL (4 mm) but reduced examination time (1 min 20 s) as well as SMS BLADE (sr) with thinner slices (3 mm) and comparable examination time (3 min 16 s). In addition, 3D SPACE was acquired in a sagittal orientation (5 min 36 s). The short axis of the cervix and the long axis of the corpus uteri were reconstructed in 1-mm and 3-mm SLs, retrospectively. Subjective overall image impression, delineation of anatomy/organs, lesion demarcation, and motion artifacts were assessed using a 5-point Likert scale and compared among the different techniques. The preferred sequence was then selected by three independent assessors. RESULTS: The analysis was based on 38 women (mean age, 44 ± 15 years). The overall image impression was similar for stBLADE, SMS BLADE (sr), and SMS BLADE (tr) but was significantly lower for 3D SPACE than stBLADE (p = 0.01). SMS BLADE (sr) was considered the preferred sequence because of slightly better performance in terms of overall image impression, organ delineation, and lesion demarcation, but without statistical significance. Both SMS BLADE (tr) and (sr) produced significantly fewer motion artifacts than stBLADE (p < 0.01 and p = 0.01), with no significant difference between SMS BLADE (tr) and (sr), while 3D SPACE had a significantly lower rating than stBLADE (p < 0.01). Image quality was rated as the least diagnostic criterion in all sequences and all cases. CONCLUSION: SMS BLADE (sr) was the preferred sequence for MRI of the female pelvis, with higher sr than stBLADE. SMS BLADE (tr) may also be used to reduce the acquisition time without compromising image quality. Despite its lower image quality, 3D SPACE can also reduce the examination time and improve the workflow because of the possibility of retrospective multiplanar reconstructions.


Subject(s)
Magnetic Resonance Imaging , Pelvis , Humans , Female , Adult , Middle Aged , Retrospective Studies , Prospective Studies , Magnetic Resonance Imaging/methods , Pelvis/diagnostic imaging , Uterus/diagnostic imaging , Artifacts
14.
Diagnostics (Basel) ; 12(4)2022 Mar 23.
Article in English | MEDLINE | ID: mdl-35453833

ABSTRACT

BACKGROUND: Laparoscopic surgery (LS) requires CO2 insufflation to establish the operative field. Patients with worsening pain post-operatively often undergo computed tomography (CT). CT is highly sensitive in detecting free air-the hallmark sign of a bowel injury. Yet, the clinical significance of free air is often confounded by residual CO2 and is not usually due to a visceral injury. The aim of this study was to attempt to quantify the residual pneumoperitoneum (RPP) after a robotic-assisted laparoscopic prostatectomy (RALP). METHODS: We prospectively enrolled patients who underwent RALP between August 2018 and January 2020. CT scans were performed on postoperative days (POD) 3, 5, and 7. To investigate potential factors influencing the quantity of RPP, correlation plots were made against common variables. RESULTS: In total, 31 patients with a mean age of 66 years (median 67, IQR 62-70.5) and mean BMI 26.59 (median 25.99, IQR: 24.06-29.24) underwent RALP during the study period. All patients had a relatively unremarkable post-operative course (30/31 with Clavien-Dindo class 0; 1/31 with class 2). After 3, 5, and 7 days, 3.2%, 6.4%, and 32.3% were completely without RPP, respectively. The mean RPP at 3 days was 37.6 mL (median 9.58 mL, max 247 mL, IQR 3.92-31.82 mL), whereas the mean RPP at 5 days was 19.85 mL (median 1.36 mL, max 220.77 mL, IQR 0.19-5.61 mL), and 7 days was 10.08 mL (median 0.09 mL, max 112.42 mL, IQR 0-1.5 mL). There was a significant correlation between RPP and obesity (p = 0.04665), in which higher BMIs resulted in lower initial insufflation volumes and lower RPP. CONCLUSIONS: This is the first study to systematically assess RPP after a standardized laparoscopic procedure using CT. Larger patients tend to have smaller residuals. Our data may help surgeons interpreting post-operative CTs in similar patient populations.

15.
In Vivo ; 36(2): 678-686, 2022.
Article in English | MEDLINE | ID: mdl-35241522

ABSTRACT

BACKGROUND/AIM: The effective atomic number (Zeff) and electron density relative to water (ρe or Rho) of elements can be derived in dual-energy computed tomography (DECT). The aim of this phantom study was to investigate the effect of different photon energies, radiation doses, and reconstruction kernels on Zeff and Rho measured in DECT. MATERIALS AND METHODS: An anthropomorphic head phantom including five probes of known composition was scanned under three tube-voltage combinations in DECT: Sn140/100 kV, 140/80 kV and Sn140/80 kV with incremented radiation doses. Raw data were reconstructed with four reconstruction kernels (I30, I40, I50, and I70). Rho and Zeff were measured for each probe for all possible combinations of scan and reconstruction parameters. RESULTS: DECT-based Rho and Zeff closely approached the reference values with a mean and maximum error of 1.7% and 6.8%, respectively. Rho was lower for 140/80 kV compared with Sn140/100 kV and Sn140/80 kV with differences being 0.009. Zeff differed among all tube voltages with the most prominent difference being 0.28 between 140/80 kV and Sn140/100 kV. Zeff was lower in I70 compared with those of I30 and I40 with a difference of 0.07. Varying radiation dose yielded a variation of 0.0002 in Rho and 0.03 in Z, both considered negligible in practice. CONCLUSION: DECT comprises a feasible method for the extraction of material-specific information. Slight variations should be taken into account when different radiation doses, photon energies, and kernels are applied; however, they are considered small and in practice not crucial for an effective tissue differentiation.


Subject(s)
Photons , Tomography, X-Ray Computed , Computers , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/methods
16.
Cancers (Basel) ; 14(2)2022 Jan 12.
Article in English | MEDLINE | ID: mdl-35053530

ABSTRACT

OBJECTIVE: To report the outcomes of active surveillance (AS) for low-risk prostate cancer (PCa) in a single-center cohort. PATIENTS AND METHODS: This is a prospective, single-center, observational study. The cohort included all patients who underwent AS for PCa between December 1999 and December 2020 at our institution. Follow-up appointments (FU) ended in February 2021. RESULTS: A total of 413 men were enrolled in the study, and 391 had at least one FU. Of those who followed up, 267 had PCa diagnosed by transrectal ultrasound (TRUS)-guided biopsy (T1c: 68.3%), while 124 were diagnosed after transurethral resection of the prostate (TURP) (T1a/b: 31.7%). Median FU was 46 months (IQR 25-90). Cancer specific survival was 99.7% and overall survival was 92.3%. Median reclassification time was 11.2 years. After 20 years, 25% of patients were reclassified within 4.58 years, 6.6% opted to switch to watchful waiting, 4.1% died, 17.4% were lost to FU, and 46.8% remained on AS. Those diagnosed by TRUS had a significantly higher reclassification rate than those diagnosed by TURP (p < 0.0001). Men diagnosed by targeted MRI/TRUS fusion biopsy tended to have a higher reclassification probability than those diagnosed by conventional template biopsies (p = 0.083). CONCLUSIONS: Our single-center cohort spanning over two decades revealed that AS remains a safe option for low-risk PCa even in the long term. Approximately half of AS enrollees will eventually require definitive treatment due to disease progression. Men with incidental prostate cancer were significantly less likely to have disease progression.

17.
Acta Radiol ; 63(10): 1353-1362, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34647842

ABSTRACT

BACKGROUND: Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. PURPOSE: To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. MATERIAL AND METHODS: A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. RESULTS: The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. CONCLUSION: We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.


Subject(s)
Computed Tomography Angiography , Contrast Media , Angiography/methods , Computed Tomography Angiography/methods , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio , Thorax , Tomography, X-Ray Computed/methods
18.
Medicine (Baltimore) ; 100(41): e27478, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34731126

ABSTRACT

ABSTRACT: The COVID-19 pandemic has challenged institutions' diagnostic processes worldwide. The aim of this study was to assess the feasibility of an artificial intelligence (AI)-based software tool that automatically evaluates chest computed tomography for findings of suspected COVID-19.Two groups were retrospectively evaluated for COVID-19-associated ground glass opacities of the lungs (group A: real-time polymerase chain reaction positive COVID patients, n = 108; group B: asymptomatic pre-operative group, n = 88). The performance of an AI-based software assessment tool for detection of COVID-associated abnormalities was compared with human evaluation based on COVID-19 reporting and data system (CO-RADS) scores performed by 3 readers.All evaluated variables of the AI-based assessment showed significant differences between the 2 groups (P < .01). The inter-reader reliability of CO-RADS scoring was 0.87. The CO-RADS scores were substantially higher in group A (mean 4.28) than group B (mean 1.50). The difference between CO-RADS scoring and AI assessment was statistically significant for all variables but showed good correlation with the clinical context of the CO-RADS score. AI allowed to predict COVID positive cases with an accuracy of 0.94.The evaluated AI-based algorithm detects COVID-19-associated findings with high sensitivity and may support radiologic workflows during the pandemic.


Subject(s)
Artificial Intelligence/standards , COVID-19/diagnosis , Lung/diagnostic imaging , Aged , Aged, 80 and over , COVID-19/epidemiology , COVID-19 Nucleic Acid Testing/standards , Feasibility Studies , Female , Humans , Lung/pathology , Male , Middle Aged , Pandemics , Retrospective Studies , SARS-CoV-2 , Tomography, X-Ray Computed
19.
Cent European J Urol ; 74(3): 453-458, 2021.
Article in English | MEDLINE | ID: mdl-34729237

ABSTRACT

INTRODUCTION: Occurrence of urinary calculi is a common medical condition. Since treatment and prevention measures depend on the type of stone found, reliable diagnostic tools are required. Dual energy computed tomography (CT) allows for rough classification of the stones found. After extraction, stone composition can be confirmed by laboratory analysis.We investigated to which degree gratings-based X-ray interferometry, which can measure attenuation, refraction and scattering (dark-field) properties of samples, allows for the discrimination of urinary stone type by calculating the ratio (R) of attenuation and scattering signals. MATERIAL AND METHODS: In an experimental setup we investigated 322 renal stone fragments from 96 patients which were extracted during routine clinical practice. Laboratory analysis showed the chemical composition of the urinary stones.These were correlated with dark field analysis of the stone samples. Measurements were performed on a X-rays gratings interferometer prototype. The attenuation, refraction and scattering signals were measured and the R-value calculated. RESULTS: The spread of R-values of a given type of calculi is large, reducing the specificity of the method. Only uric acid stones can reliably be distinguished (sensitivity of 0.86 at a specificity of 0.9) from the other stones. CONCLUSIONS: Gratings-based dark-field imaging is a non-destructive and potentially non-invasive technique that allows to discriminate between uric acid and non-uric acid stones, which from a clinical point of view represents by far the most important question for stone treatment.

20.
In Vivo ; 35(6): 3147-3155, 2021.
Article in English | MEDLINE | ID: mdl-34697145

ABSTRACT

BACKGROUND/AIM: The quantitative evaluation of fat tissue, mainly for the determination of liver steatosis, is possible by using dual-energy computed tomography. Different photon energy acquisitions allow for estimation of attenuation coefficients. The effect of variation in radiation doses and reconstruction kernels on fat fraction estimation was investigated. MATERIALS AND METHODS: A six-probe-phantom with fat concentrations of 0%, 20%, 40%, 60%, 80%, and 100% were scanned in Sn140/100 kV with radiation doses ranging between 20 and 200 mAs before and after calibration. Images were reconstructed using iterative kernels (I26,Q30,I70). RESULTS: Fat fractions measured in dual-energy computed tomography (DECT) were consistent with the 20%-stepwise varying actual concentrations. Variation in radiation dose resulted in 3.1% variation of fat fraction. Softer reconstruction kernel (I26) underestimated the fat fraction (-9.1%), while quantitative (Q30) and sharper kernel (I70) overestimated fat fraction (10,8% and 13,1, respectively). CONCLUSION: The fat fraction in DECT approaches the actual fat concentration when calibrated to the reconstruction kerneö. Variation of radiation dose caused an acceptable 3% variation.


Subject(s)
Fatty Liver , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Photons , Radiation Dosage
SELECTION OF CITATIONS